SOLARTODO Administration | English operator training 00:00:00 Fleet overview and alarm queue After signing in, open Overview. Equipment, Online now, Unbound and Accounts are fleet totals. Open Alarms to handle and check the equipment, reported condition and time before acting. Return to the overview and open Details for Training Pivot 02. It is a registered training record with no controller reporting. Check the connection indication before assuming a machine is available. The alarm queue and the equipment in this example run on a private training environment. 00:00:33 Register equipment and select a machine type Choose Equipment, then Register equipment. Enter the approved equipment identifier and display name, and select the actual machine type. This example registers a center pivot with an English display name. Review all fields and save. A one-time claim code is generated for the intended owner, and the demonstration conceals it. Close the code panel, search for Training South Pivot, and verify the row and unbound status. The registration creates an administrative record. Connecting and commissioning the controller are separate steps. 00:01:11 Edit an existing equipment record In Equipment, locate the existing machine by its permanent identifier. Select Edit record and review the native name and the optional English display name. Update both names in this training example. Save, then check that the inventory shows the new display name alongside the same equipment ID. This is an edit to an existing record. It leaves the binding and operating geometry as separate actions. Verify the identifier before changing a similarly named machine. 00:01:44 Installation, positioning and tower reports Open Details for Demo Field Pivot and locate Installation geometry. Before entering coordinates or dimensions, compare the fields with the approved survey and installed machine type. Close the installation form and continue to Dual GPS positioning. Compare the center receiver, the end receiver and the time of each fix. In Tower status, distinguish a reported condition from an empty or stale reading. The positioning values here come from a loopback fixture. Survey accuracy and actual tower inputs require a site check. 00:02:21 Save geometry and approve a machine-type change Open Installation geometry for the separate training record. The center-pivot form uses center coordinates and operating radius. Switching to lateral changes the form to a travel origin, a travel end point and the machine span. The console requests explicit confirmation before it changes the registered machine type. Enter the demonstration values, confirm the type change, then save and verify the inventory row again. These figures are examples only. Use the actual site survey and approved machine type when commissioning equipment. 00:02:59 Replace a claim code and verify ownership In Claim codes, search for Training Pivot 02 and choose Ready to claim. Check the equipment and expiry before selecting Issue new code. The warning explains that a replacement invalidates the earlier code. Keep either the code or its QR private when you hand it to the intended owner. In this example the owner-side service confirms the claim in the isolated environment. Refresh the desk, choose Bound, and open View owner. Verify the displayed identity and equipment before handing over access. 00:03:35 Release equipment ownership for a transfer Open Equipment and locate Training Transfer Pivot. Confirm the registered owner and read the existing binding before selecting Release. The confirmation explains that existing members lose their access to that equipment. Proceed only after the transfer is approved. Refresh the inventory and verify that the correct machine reads Unbound. The resulting record remains in the inventory. A new owner will need a new claim-code handoff and their own authorization before operating the machine again. 00:04:09 Edit and send an irrigation program In Equipment Details, open Irrigation program and expand Edit plan. Name the plan and inspect the sector endpoints, direction, timer percentage and water mode. This example uses a dry training sector. Save the plan, then expand Device feedback and revisions. Saving updates the management record. Use the separate Send to device control, then compare the saved revision with the returned revision. A matching revision verifies delivery in this local exercise. Check installed travel and water feedback during site commissioning. 00:04:47 End-gun sectors and electronic stop boundaries In the irrigation program editor, add a scheduled end-gun sector and enter its start and end positions with the intended direction. Add an electronic boundary and choose its position, direction and stop action. The alternate action requests reversal and exposes a reversal-limit setting. Open Preview travel sequence and select Preview forward. This dry sector suppresses the scheduled end gun. Review the order before saving. Surveyed boundaries and timer percentages are configuration values. This exercise saves the plan locally without sending or running it. 00:05:27 Manual control and independent feedback Open Manual Control for the authorized demo machine. Select the direction and read the confirmation before starting. Once the example is running, inspect Control receipts and input feedback. The command and the input report answer different questions. Select Stop machine and wait for the run and direction contacts to open. This console is driving an isolated software fixture that supplies the input reports. At a field installation, check physical standstill and any separate water or end-gun feedback. 00:06:02 Manual end-gun and main-sprinkler feedback In Equipment Details, open Manual Control and find the end gun and main sprinkler controls. Confirm the selected equipment and the command before requesting an end-gun change. Read the separate feedback row after turning it on and again after turning it off. On this fixture the main sprinkler contact reports on independently. Turn it off before stopping. Check the installed inputs when a feedback state is unknown. The loopback fixture confirms contact behavior only, without live water flow. 00:06:37 Match the archived reverse-start and stop receipts Open Equipment and then Details. In Control receipts and input feedback, read the Command, Receipt, Verification and Command ID columns. Selecting Reverse records an applied direction output with unverified contact feedback. The reverse start has its own ID and a contact-confirmed result. The stop has a different ID, with all eight input contacts open in the archive. These are imported hardware bench records. The original export supplied no per-command server timestamps, and the date cells are left blank. 00:07:14 Agricultural monitoring and probe types Open Agricultural monitoring and select Demo Field Pivot. The workspace groups installed probes and available device types. Read categories and measurement names before requesting a probe. An inventory entry describes capability, while the device panel shows equipment-specific reports and their freshness. In this exercise the listed examples belong to the demonstration workspace. Verify the actual probe support, interface, supply, address and installation method before planning field wiring or promising a particular measurement. 00:07:52 Issue and activate a sensor probe In Agricultural monitoring, select the intended equipment and open the probe provisioning controls. Enter the approved probe identity and issue its activation code. Keep the code and QR private. In the activation form, confirm the equipment, probe profile and serial address before submitting. Then find the probe in the active inventory. An activation record can appear before any readings arrive. Open a reporting probe to compare the first sample, units and report time. The sample values here are generated for training. 00:08:29 Import historical readings and export CSV In the selected machine, open the archived probe and expand History files and records. Download the CSV template, keep the headers, and use a valid timestamp with the corresponding units. Choose the sample file and select Import readings. Review the inserted and duplicate counts before relying on the archive. Then select the machine-wide CSV export and verify that a file is downloaded. Imported history is stored separately from a fresh sensor report. This file contains sample data. 00:09:04 Import and view historical field photos Choose Agricultural monitoring and select the correct machine. Expand the file-based Field photo record and open Field photo history. Choose an approved JPEG or PNG and enter its actual local capture time. Import the file, then select its dated thumbnail to inspect the saved image. Refresh or load earlier images when they are available. This upload uses a training image. The gallery stores historical photos from an operator, separate from security camera video and live telemetry. 00:09:39 Acknowledge a cable protection alarm Open Cable security and select the example equipment. Review the segment, reported power state and time before acknowledging the alarm. Changing the alarm workflow records that an operator has reviewed it. Read the updated status and record a disposition after checking what the event actually means. Open the segment settings and inspect Alarm platform integration for read-only access. This is a training alarm. No field cable detector, physical damage, backup runtime or external delivery is verified by this recording. 00:10:16 Classify and filter the enabled cable alarm types In Cable security, open the fleet alarm queue. Read each title and reported condition separately from its workflow status. This exercise shows a cable loop anomaly, mains loss, terminal offline, low battery and enclosure tamper as distinct example conditions. Choose Active only or Include recovered, and use Alarm workflow and equipment ID to narrow the queue. Open View equipment to confirm which machine reported an event. The test conditions are injected into the isolated workspace. 00:10:52 Issue, rotate and revoke a read-only alarm key In Cable security, choose a bound machine and scroll to Alarm platform integration. Select Issue key, review the confirmation, and save the displayed value privately. Its value is masked here. Select Done and verify Read-only feed enabled. Rotate the key when the receiving system needs a replacement. Revoke the key when access should end and confirm that the feed reads Not enabled again. An external read-only feed can inspect allowed alarms. It cannot acknowledge alarms or operate equipment. 00:11:28 Add, link and remove a security camera Open Security cameras and select the equipment. Choose Add camera, enter its display name and authorized HTTPS viewer, and add a playback link when available. Link the camera to a cable segment if appropriate, then save. The card confirms that the configuration was stored and identifies the association. Verify the name before selecting Remove and confirming. The updated list shows that only the selected training entry was removed. The example URLs have no live or recorded camera feed. 00:12:04 Look up an AI membership entitlement In AI memberships, enter the account and choose the current subscription period. Search and read the provider, expiry and Last verified fields together. Then look up the demonstration account with no subscription to see how an ineligible account appears. Finally, search for a missing username and review No matching accounts. A missing search result is different from a recorded account without a subscription. This exercise uses seeded entitlements, with no payment, renewal or provider account operation. 00:12:39 Create an account and manage machine access In People, select Add account, enter the approved username and a temporary password, and save. Find the Active row. Open the intended equipment and scroll to Device access. Choose the account, review View only, Alarm responder and Machine operator, then save the least access appropriate for the role. Here the saved role is View only. Return to People, review the Disable confirmation, and check that the correct account becomes Disabled. Machine access and system account status are separate controls. 00:13:15 Administration audit and interface language Open Audit trail to see administrative actions such as account and access changes. Read the time, event, actor and equipment. Open the equipment record separately to review runtime activity and control receipts. Use the language selector at the top of the workspace to switch to French and then return to English. The labels change while the equipment record stays the same. The console supports eight interface languages. This training environment uses demonstration identities and equipment.