Desktop review · EnglishStart in reverse. Verify the stop.
Owner App and admin command history · Bench session on 13 November 2026
Open the complete English training libraryDownload MP4 · Download English subtitlesDownload timed English script
Compare the App and admin receipts
The owner and admin returned the same result for each command ID below. Inputs are shown at the time of the recorded receipt. Commands 119 and 120 account for the two end-gun tests between starting and stopping.
| Sequence | Action | Owner and admin | Bench inputs | Shared command ID |
|---|---|---|---|---|
| #117 | Select Reverse | Output applied | All open | e0ef2844-8ba5-4674-838b-658ec110565f |
| #118 | Start in reverse | Feedback confirmed | Run and reverse closed | 18118323-a33a-401b-bb99-9444adcecab9 |
| #119 | End gun on | Feedback confirmed | Run, reverse and end gun closed | 508f163b-a75c-4b33-a30f-5dbfb1e5ca75 |
| #120 | End gun off | Feedback confirmed | Run and reverse closed | beb41476-b3d0-4441-bdce-2e8a2193a6f3 |
| #121 | Stop | Feedback confirmed | All open | bde4e46d-933b-4338-aecf-cb0287793166 |
The hardware test measured electrical contacts. The video replays the stored results in SOLARTODO editions of the owner App and admin console from the November 16 release. The pivot name and map are for demonstration. Its editing pace is independent of the original timing.
Read the English script
In the owner App, open Control. Check the name, Demo Field Pivot, and the travel status, Stopped. Now open Manual Control.
Under Travel control, tap Reverse. The status still says Stopped. Command 117 set the direction. All three travel contacts are still open.
Tap Start in reverse. Check the machine name and direction in the review. Tap Confirm reverse start once. The request is in. Now wait for the contacts.
There it is: Running in reverse. The run and reverse contacts are both closed. The forward contact stayed open. That is the bench feedback for command 118.
Tap the red Stop button once. Watch the travel status return to Stopped. On command 121, both travel contacts released. All eight controller outputs were off.
In the admin console, open Equipment, choose the pivot, and find Control receipts and input feedback. Find Start travel, Reverse. Match the command ID, then read across: Field feedback confirmed. Contact feedback.
The two end-gun tests sit between start and stop in this session. Find Stop travel and match its ID. Both the owner and admin receipts confirm the stop. All eight inputs were open.