01 Open Equipment
Tap Equipment on the bottom navigation. Find the center pivot by its site name.
Check The selected pivot is marked in the list and shown in the header.

Follow the SOLARTODO owner App and administration console with full-screen examples. The walkthrough uses training records and simulated machine feedback.
Download the English operator guide · Field wiring guide
Task 01 · Fields
This guide shows simulated GPS reports on USDA NAIP aerial imagery of a U.S. demonstration field. Map services and data available from U.S. Geological Survey, National Geospatial Program.
Tap Equipment on the bottom navigation. Find the center pivot by its site name.
Check The selected pivot is marked in the list and shown in the header.

Choose North Field Pivot. The training account contains two pivots so you can see the difference.
Check North Field Pivot replaces the previous target in the header. It is offline in this rehearsal.

Return to Demo Field Pivot. Tap Fields, open Location, then select Satellite. Tap Fit GPS to center the map on the pivot.
Check The heading names the selected pivot and the map shows both receiver markers.

Find marker A at the pivot center and marker B at the end receiver. Scroll to Head and tail positions to read the two report times.
Check Read the timestamps for A and B. If B says Last known position, use its timestamp to judge how old the fix is.

Task 02 · Fields
Review where the pivot was previously reported and inspect a selected instant.
Open Fields and tap Playback.
Check The heading indicates a recorded track and still names the active machine.

Open the track filter. Set the from and to dates, then load the records for this machine.
Check The period and reported sample counts appear in the track area.

Scroll to playback and inspect the number of usable fixes. A record without a fix may have no plottable location.
Check The timeline corresponds to recorded reports, not the current state.

Tap Play and watch the marker and time advance.
Check The recorded position moves along the timeline when there are consecutive usable fixes.

Open the speed control. Choose a lower speed for short intervals or a higher speed for longer histories.
Check The speed changes the playback clock only.

Tap Machine 3D beside the timeline and scroll to the viewer. Drag the model to see it from another angle.
Check The viewer is in historical playback. Pose unavailable means the illustration shows the machine layout without a measured pose for that instant.

Tap Location to return to the live field view.
Check The heading changes from recorded history to the machine’s live field view.

Task 03 · Control
Follow the manual command from direction selection through independent run and stop feedback.
In Control, read the pivot name and last contact time. Verify that the machine is stopped.
Check The header says Demo Field Pivot and the status reads Stopped.

Tap Manual Control below the plan summary.
Check The direction buttons and Start control are visible.

Tap Reverse. This selects the requested direction for the next start.
Check Reverse is selected and the machine still reports Stopped.

Read the device name and Reverse direction. Cancel if either is wrong.
Check The full-screen confirmation shows the selected machine and separate confirmation.

Confirm the reverse start once cleared. Read the response while the controller obtains feedback.
Check Command submitted comes before the machine’s independent run and direction confirmation.

Wait for Running in reverse and read last contact. The simulator supplied independent run and reverse inputs in this session.
Check Both returned inputs are represented by the run status. The main water supply feedback shows off in the example.

Tap Stop while observing the selected equipment name.
Check The app reports progress before the input proving the run has stopped clears.

Wait for Stopped and confirm the newest status. Follow local procedures to confirm actual standstill at an installed site.
Check The run and reverse inputs are clear in this training session.

Open Activity on the same pivot. Find the stop and start-related records.
Check The latest command card reports contact feedback; the history lets you correlate commands with their results.

Scroll through Activity to the start entry. Correlate the time and direction with the stop on the same pivot.
Check The same history shows the Reverse request and its recorded outcome.

In Administration, select Equipment > Demo Field Pivot > Details. Under Equipment activity, locate the stop and reverse-start records from this same rehearsal.
Check Compare the same equipment, action, result and time with Activity from the owner session.

Task 04 · Control
Identify which feedback is missing and establish whether the machine is available for local or remote control.
With the simulator stopped, open Manual Control and choose Forward.
Check Direction selection and a start command are distinct.

Review the machine and direction before submitting the isolated start trial.
Check The screen identifies the forward start without changing the machine selection.

Confirm the isolated start without supplying the independent forward feedback in the simulator.
Check The command is waiting for the machine; the initial reply does not establish movement.

After the configured waiting period, read the message and the latest reported state.
Check The training fault is intentionally induced; the displayed reason determines the next investigation.

After the authorized stop attempt, open Activity on the same pivot.
Check Review the returned stop result and retain the earlier trial record for support.

Task 05 · Control
Find the two water functions and read the return for each connected output.
Expand Manual Control. Scroll past Travel control to the water sections.
Check Main water and the end gun have separate controls.

Read the main water feedback label beside its buttons. If an authorized site has a working supply circuit, operate its switch under the site procedure.
Check The visible feedback describes the returned supply input. Use site observation to verify water.

Review the main sprinklers confirmation. Confirm only when the correct circuit and site conditions are known.
Check The requested circuit is named and endpoint status remains separate.

The simulator supplies an independent main-water input for the selected circuit. Read the label after the return.
Check A contact may indicate the expected equipment state. A field pressure or flow check is still required to establish actual discharge.

Continue to End gun. Review the independent feedback and switch controls.
Check End gun feedback does not confirm main supply or measured discharge.

Review the choice in the confirmation area before applying it.
Check The dialogue names the end gun output and leaves the main supply separate.

Read the latest end gun feedback after the request.
Check The simulated contact is a device-side return, not proof of water.

Task 06 · Control and Fields
Prepare an example work plan with a travel sector and a stop rule.
On the selected pivot’s plan card, tap Edit. Read the existing name before touching any rule.
Check The work plan appears within the active pivot’s control screen.

Open Pick on diagram. Use the diagram to check orientation before editing numeric values.
Check The visual span and the numeric plan must agree for the selected center pivot.

Expand the travel-zone row. Check the start, end, direction and speed. The example starts at 28° and ends at 111°.
Check The direction and water mode are separate from the sector boundary.

Select the wet mode to review the depth field, then restore Dry for this rehearsal.
Check Selecting a water mode is a plan edit. It does not provide a water reading.

Expand the end gun range and compare its endpoints. Use the range or switch back to manual control to match the reviewed plan.
Check The gun has a separate range and the editor shows whether automatic or manual control is selected.

Add a stop boundary and check its position, direction and action before saving.
Check The boundary belongs to this work plan. It is not yet a physical parking result.

Scroll to the action area. Tap Cancel when exploring. Save plan is used when the revised parameters are approved.
Check The action is explicit. Saving a revision is separate from starting movement.

Return to the plan summary after Save plan.
Check Check the saved work-plan name. Device synchronization and execution are covered in the next task.

Task 07 · Control and Fields
Verify that a saved plan can be used by the correct machine and understand what an actual device return means.
Tap Fields and choose the Work plan or rules tab.
Check The page names the same pivot and identifies its saved work plan.

Locate Sync plan or Review start under the work-plan summary. Verify the selected machine and saved plan.
Check If the action is disabled, resolve the reason before continuing.

In the plan review, read the direction options and confirm the intended travel direction.
Check The selection applies to this run. The simulator will preserve the separation between review and movement.

Read Hold to start after choosing a direction. The move is requested only after the hold completes or the accessibility confirmation is accepted.
Check The screen shows the chosen direction and a distinct start control.

Keep holding until the control says Release to start. Release only when the approved direction and field conditions are clear.
Check The actual hold-and-release gesture is distinct from selecting the direction.

Wait for the plan and movement response. The isolated scenario supplies a run signal independently from the app submission.
Check Treat a missing start response as unresolved.

Watch the indicated position cross the 55° boundary in the isolated training plan.
Check The reported automatic stop is still a software and contact-input demonstration, separate from measured field stopping distance.

Use Switch to manual when the plan must stop, then wait for the device to return control.
Check The handover must complete before the manual controls accept movement.

Open Activity for the same pivot after stopping.
Check The stop command and device return can be checked by their timestamps.

Task 08 · Sensors
Assign an approved probe to the selected pivot and check whether it has actually reported a reading.
Tap Sensors, then the agricultural monitoring module. Open Registered probes.
Check The machine name and existing probe count identify the list.

Open Catalog to identify the required type. Return to Registered probes when ready to bind.
Check The catalog shows supported types. It does not show that a particular probe has joined the machine.

Tap Activate device. Enter the administrator-issued code or use the scanner when available.
Check The form names the selected pivot and separates the activation code from the type.

Open the type selector and search for soil. Check the reading types against the installed probe.
Check Choose the sensor type supported by the actual installation.

Make sure the code and selected type match before tapping Activate. The training code is masked in the screenshot.
Check The Activate button is enabled when the required fields are in place.

Return to Registered probes and look for the activation notice.
Check An awaiting-first-report count can remain until the new probe sends its first sample.

Open an existing soil probe as a reference. Read its unit, timestamp and source.
Check A sample must have a timestamp and unit before comparing it with other readings.

Task 09 · Sensors
Export a date-bounded set of readings and identify the fields that establish where each value came from.
On Registered probes, find the export panel for this machine.
Check The export is scoped to the selected equipment.

Open the export panel and choose all registered probes or one probe.
Check The selected scope and date options are visible in the same panel.

Select Custom dates. Enter valid UTC start and end dates within the allowed range.
Check The UTC label defines how to interpret the selected dates.

Choose 7 days and press Download CSV.
Check The browser downloads a CSV for the active machine and period.

Keep the export panel open to verify the download status. In the saved file, check timestamp, probe, metric, value and unit.
Check A successful request can still have an empty set of samples. Compare with the on-screen timestamp.

For a file-based measurement source, expand History files and records. Download the template when the column names are unknown.
Check A historical archive is attached to a specific measurement profile.

Choose the completed file. Check that sampled_at, checked units, and source columns use the template’s expected format.
Check The selected filename is shown with the import button.

Click Import and verify the displayed results. Refresh history to inspect the timestamp and stored reading.
Check The imported row belongs to the archive and can now be queried separately from live telemetry.

Task 10 · Sensors
Find an alert, record that it was seen, and preserve a separate handling note.
From Sensors, choose the cable protection module for the highlighted pivot.
Check The module shows a cable segment assigned to this machine.

Open the named segment and inspect its reporting time and condition.
Check Make any field decision from a fresh indication and local verification.

Open the alert and review the kind, segment, time and source.
Check Status such as Unresolved does not identify who has acknowledged it.

Scroll within the expanded alert to Acknowledge alert.
Check Your acknowledgment is separate from the equipment’s physical status.

Check the alert after acknowledging it. The event remains available while the investigation continues.
Check The workflow now records that someone has seen the alert.

Enter what was checked and who should follow up. Choose Mark handled only if the handling record is ready.
Check The note is attached to this incident and should distinguish knowns and open work.

Switch to the alert history and confirm the event is included.
Check Read the original segment and recorded workflow result together.

Task 11 · Sensors
Check which camera links belong to the selected machine or protected segment.
On Sensors, choose Security for Demo Field Pivot.
Check The selected pivot stays in the header.

Scroll to Cameras. Read the camera name and its segment. Use View camera or View playback where offered.
Check Connection unverified is a prompt to test the actual camera link. No field stream is playing in this training view.

For comparison, open Security for the other training pivot.
Check If no camera is configured for the selected machine, the empty state appears.

Task 12 · AI
Understand account entitlement, review data coverage and trace trends back to their readings.
Open AI and read the entitlement, renewal information where supplied, and the monthly AI price.
Check This training account is Active. The displayed AI charge is separate from the annual control platform.

Scroll to the analysis method and time interval.
Check The report covers the account and selects a seven-day time window.

Open the scope and data-source section. Compare count coverage before interpreting changes.
Check A sample associated with another sensor, device or source cannot be interpreted as if it were your field reading.

Scroll to trends and identify a real reading, its unit and a coverage gap. Return to Sensors to check details.
Check A chart point is based on available data and does not operate the machine.

Expand a machine in the report. Use the pivot name to check what its source readings cover.
Check The detail stays within the signed-in account’s assigned equipment.

Task 13 · Equipment
Bind a newly assigned pivot and confirm the correct record before operating it.
Open Equipment and look below existing equipment for the bind button.
Check The active pivot remains visible in the header.

Tap Bind equipment. Type the code or use the available scanner.
Check A clearly scoped dialogue appears over Equipment.

If the code is not valid, read the error before trying again. Get a new code if required.
Check An invalid code does not add an equipment record.

Use the issued code to open the preview. Check the machine name, type and equipment identity before confirming.
Check A preview of South Field Pivot shows the intended record. The code is masked.

Return to Equipment and find South Field Pivot in the assigned list.
Check The equipment row verifies that the machine is now assigned.

Open Machine setup for the assigned pivot. Compare read-only values with the installation record.
Check Only authorized users should alter site geometry or setup values.

Task 14 · Activity and Settings
Find recent equipment history and keep the app in the preferred display language.
Tap Activity and read the latest command, time and result.
Check The header names the pivot whose history you are reading.

Scroll to a start or stop. Compare its result and time with the event that preceded it.
Check An equipment report, a command and its feedback may appear as separate records.

Tap the settings icon, then locate Language.
Check The displayed language and selector belong to this app session.

The same Settings view is redrawn in the selected language. Confirm navigation and controls match the account you are using.
Check This example briefly chooses French and then returns to English.

Choose your language from the live selector. Returning to English in this sample keeps field labels aligned with the manual.
Check Eight choices are installed: 中文, English, العربية, Русский, Français, Español, Português (Brasil), Türkçe.

Task 15 · Overview
Triage equipment, owner assignment and alarms from one page.
Select Overview in the sidebar. Read Equipment, Online now, Unbound and Accounts.
Check These are platform totals, not proof that any individual pivot is ready to move.

Read the Equipment monitoring cards. Select Alarms to handle to open the matching inbox.
Check The list is filtered for follow-up; a physical fault can remain Active after acknowledgment.

Check the filters, machine reference, time and condition before selecting a record.
Check The demo alarm is generated by the local training fixture.

Return to Overview and open Details for an equipment row. In this example, select Training Pivot 02.
Check Check ownership, connection and Last contact. This training record has no live controller.

In the connected demo machine, scroll to Dual GPS positioning. Read the positions and their timestamps.
Check Treat a stale fix as a last known position. The screen uses synthetic position readings.

Task 16 · Equipment
Use the inventory and the site-survey record for a confirmed machine.
Select Equipment and locate the Register equipment button. You can search by equipment name or ID.
Check Check that the machine does not already exist.

Fill Device ID and equipment name. Choose Center pivot. Add the English display name as needed.
Check Match the ID to the equipment label and confirm machine type before saving.

Save. The console issues a one-time claim code and expiry for valid handoff to the owner.
Check The training code and QR are concealed in this screenshot.

Search the newly registered name in Equipment. It remains unbound until the owner claims it.
Check The new row contains the expected name and type, with no owner yet.

In Details, select Installation geometry. Compare the fields with the approved survey; enter surveyed values only.
Check Use the recorded machine type and survey information. The example is a review, not a field survey.

Scroll to Dual GPS positioning and then Tower status. Check receiver roles and the latest readings.
Check Tower data only describe connected signals. No data is not proof of a healthy tower.

Task 17 · Equipment
Compare the saved revision and the revision reported by the machine. Separate saving and sending from starting travel.
Select Irrigation program in Details and expand Edit plan. Name the plan and review the listed sector.
Check In this example the saved geometry is used and the sector is dry.

Review the sector endpoints, intended direction, speed and water mode in the plan editor.
Check A saved boundary or dry zone is a configured rule, not a measured stop or water state.

Click Save plan. Expand Device feedback and revisions to compare the stored revision with the reported revision.
Check The saved name changes to Training dry sector. The machine can still report a different or unknown revision.

Check the selected machine, then use Send to device when it is available. The label can name a simulator or bench in other configurations.
Check The current configuration has a separate send action. The button availability can depend on session freshness and support.

Open the live feedback block again after sending and compare the saved and device revisions.
Check Proceed only after a fresh report confirms the intended revision. The training controller uses simulated inputs.

On the same authorized machine, expand Manual Control. Select a direction before using the start request. Stop is a separate action.
Check Verify site readiness and wait for independent feedback before assuming that a movement command has taken effect.

Check the machine and chosen direction in the confirmation. Submit only after preconditions are met.
Check The local simulator is isolated from physical machines.

Read the independent input feedback after command submission. In the example the simulator confirms the forward input.
Check A closed run contact plus the expected direction is separate from receipt of the command.

Use Stop machine and wait for returned inputs.
Check The demonstrator’s run and direction inputs are open. An onsite team independently verifies physical standstill.

Read the connection and feedback above the plan. Use the equipment activity below Details to check control events.
Check A command entry and independent feedback carry different information.

Task 18 · Claim codes
Hand a one-time claim code to the grower and confirm the final binding.
Select Claim codes, enter the machine name and choose Ready to claim from Claim status.
Check The row shows the correct machine, type, status and expiry.

Select Issue new code. Read the warning and check the intended machine before you generate a replacement.
Check Generating the replacement invalidates the earlier code immediately.

Use Copy claim code or the displayed QR. The owner checks the device name and type in the App before confirming.
Check The training code and QR are concealed here. Read the expiry in the real workflow.

After the owner confirms in the App, re-open or refresh Claim codes and choose Bound.
Check The intended record appears as Bound. The demonstration exercised the owner claim API in the isolated environment.

Select View owner and read the owner name in equipment details.
Check The owner matches the intended account.

In Claim codes find the unbound training pivot. Issue a new code for the authorized recipient.
Check The code and QR are concealed. The machine name, type and expiry remain visible.

In Equipment, open the bind form and enter the one-time code you were given.
Check The training code is concealed. Verify it was issued for this machine.

Read the machine name, equipment ID and type in the preview. Confirm only when they match.
Check The preview matches Training South Pivot from the web console.

Return to Equipment and find the newly claimed pivot in your list.
Check Training South Pivot is now assigned to the training owner.

Refresh Claim codes, verify Bound, then select View owner.
Check The equipment details name the same training owner.

Task 19 · Agricultural monitoring
Keep probe activation, current observations, imported histories and export separate.
Select Agricultural monitoring. Search or select the pivot, then read its Field probes panel.
Check The equipment name and existing probe list match the intended machine.

Click Issue probe code and enter the probe identifier. Expand Installation settings when a confirmed bus address should be provisioned.
Check The code is for the probe and is distinct from the machine claim code.

Issue the code. Match the code/label to the probe identifier and distribute it through the intended handoff.
Check The training code and QR are masked. The console supports printing the probe label.

Click Activate device. Enter probe ID and activation code, choose the compatible sensor type, and review the installation setting.
Check The selected type corresponds to the physical probe. The screenshot masks the activation code.

Find the newly assigned probe and read its current data status. This example has just been activated.
Check Awaiting first sample indicates the software is waiting for the first reading from the assigned field sensor.

Expand a configured probe. Confirm observation time, units and sensor identity before comparing values.
Check The open card shows the software reporting model using fresh local training readings.

Use the probe CSV template. Keep the existing headers and supply a valid timestamp and corresponding metric values. Choose the file and select Import readings.
Check The training file is explicitly historical; it does not become a fresh controller observation.

Review the imported and duplicate counts and inspect the history list.
Check The sample is available through the archived history workflow.

Use Export all · 365-day CSV for the selected equipment. Check the downloaded file and headings.
Check The training download is a real CSV from the local application. Its values are demonstrations.

Task 20 · Cable security
Review the selected cable segment and record the response to an alarm.
Select Cable security. Check workflow, equipment, segment, detection time and current condition.
Check The alarms shown were injected by the local training fixture.

Select Acknowledge, enter the note as required for your process, then confirm.
Check The alarm record keeps the note. Acknowledgment does not repair a physical fault.

Read the status, current condition and newly saved note.
Check This is a staff action. Verify the condition separately.

Select Handle and enter the requested resolution note. Confirm after the prescribed investigation.
Check The note records the operator’s action independently of the electrical condition.

In Segments and terminals, select Add segment. Match the unique segment and terminal identifiers and the required heartbeat configuration.
Check Leave the segment disabled unless the site is ready to start monitoring.

Find the new segment. Check whether it is enabled and whether it has submitted a report.
Check The training segment is disabled and has no verified field terminal.

Scroll to Alarm platform integration. Keep export/access credentials restricted to the nominated integration.
Check The integration and alarm handling are separate controls.

Task 21 · Security cameras
Manage the camera link and keep the viewer’s permissions and connection separate.
Select Security cameras and choose the intended bound machine. Read the existing camera list.
Check The camera belongs to the selected machine.

Add camera. Enter name, the HTTPS viewer address and optional playback. Select a linked cable section if applicable.
Check The examples are reserved training URLs. In the field check that the addresses are authorized.

Read the name, associated section and Connection unverified status. Edit or review the viewer as appropriate.
Check The local console saved the camera record. A working viewer requires separate validation.

In the intended entry select Remove and review the confirmation. Select Confirm removal only when the owner has approved the change.
Check Check the camera name before proceeding.

Review the refreshed list. The removed training camera is gone.
Check The other equipment camera remains listed.

Task 22 · AI memberships
Read the latest verified entitlement status for an account.
Select AI memberships, enter the account and choose Current period, then select Search.
Check Review the provider, expiry and Last verified. The example is a synthetic entitlement with no charge.

Search the second training account and choose No subscription.
Check No subscription is shown instead of assuming the account is eligible.

Search a username that does not exist in the training workspace.
Check No matching accounts means the search/filter has no match; recheck the name and filters.

Task 23 · People
Assign the least access needed at the correct machine.
Select People then Add account. Fill the approved username and a temporary password that satisfies the length requirement.
Check The password field is masked. Use your approved handoff for initial credentials.

Save the account and look it up under Accounts & access.
Check The new user is Active. Machine permissions are assigned separately.

In Details scroll to Device access. Select the user and check the Assigned role options. Choose View only, Alarm responder or Machine operator as approved.
Check Responders can handle alarms. Operators can also send authorized commands. The role here is per equipment.

Select Save access, then read the saved role beside the selected user.
Check The example shows the training user with View only for this pivot.

Under People select Disable beside the correct user and review the confirmation.
Check Disabling an account revokes active login sessions.

Confirm and read the updated state in the accounts table.
Check The Disabled status belongs to the intended training account.

Task 24 · Audit trail
Trace who changed accounts, equipment records and ownership, and where to find travel events.
Select Audit trail and review Time, Event, Actor, Equipment and Details.
Check The top rows contain operations from this local training session.

Match the event time and actor to the approved account or equipment change.
Check Compare the event with the outcome shown in People or the equipment record.

Open Equipment, choose Details for the target machine and scroll to the activity section.
Check Equipment-level entries show specific command and equipment results, including feedback where available.
